CONNECTIONS
Data and Power :
Data connections should always be made using screened cable. This will ensure maximum rejection of
interference from outside interfering sources. Always use a common ground point.
The RTcom Global, Europa and Outback modems support RS232, RS422 and RS485
communications, both 2 and 4 wire. The RS232 port should be used for short cable runs of up to 10m and
the RS422 and RS485 can be used for extended distances. The modems support various data rates from
1200 to 9600bps depending upon version. All units support 7- and 8- bit ASCII data with even or odd parity
and 1 or 2 stop bits.
Terminal Number Designation WRT
Modem (-Global)
Notes
1 +24V dc supply Supply
2 GND Ground
3 +12V dc supply Supply/Ground
4 GND Ground
5 DTR Optional not
normally needed
6 DCD Optional not
normally needed
7 TXD (RS232) Output data from
modem
8 RXD (RS232) Input data to
modem
9 Z = TX (-) RS485 / RS422
10 Y = TX (+) “
11 A = RX (+) “
12 B = RX (-) “
13 GND Ground
Tab. 1 : Connections for the Global Modems
Terminal Number Designation WRT Modem Notes
1 +24V dc supply
2 GND Ground
3 +12V dc supply
4 GND Ground
5 TXD (RS23) Output data
from modem
6 RXD (RS232) Input data
to modem
7 Y = TX (+) RS485 / RS422
8 Z = TX (-) “
9 B = RX (-) “
10 A = RX (+) “
11 GND Ground
Tab. 2 : Connections for the RTcom – Europa Modem